CURRENT LOCATION:

Home / About/News

Common faults and troubleshooting of wire rope electric hoists

2025-10-22

rizhi

Common Faults and Solutions for Wire Rope Electric Hoists: - No operation: Check the power supply, fuses, and whether the control cable is broken. - Braking failure (the hoist slides down): Adjust the brake clearance or replace the brake pads. - Abnormal noise or overheating from the motor: Check if the motor is missing a phase, if the bearings are damaged, or if the hoist is being used beyond its capacity. - The wire rope is tangled or has come off the drum: Ensure that the wire rope is properly wound around the drum and that the guide rollers are in good condition.